                Prep-Room and Surgery Suite Checklist
- Turn oxygen ON
 
- Turn alarm ON
 
- Turn scavenger system ON
 
Prep-Room
- Clean/disinfect exam table
 
- Clock with second hand
 
- Hair clipper with #40 blade
 
- Spare #40 blade
 
- Blade cleaner
 
- Vaccum/Dustbuster
 
- Scrub solution/alcohol/sterile sponges/sterile hand towel/topical spray (depending on your hospital protocol)
 
- Garbage can
 
- Anesthesia machine – see our “Basic Anesthesia Machine Set-Up”
 
- Stethoscope
 
- Pulse Ox and wet gauze pads to help keep the tongue moist
 
- Portable crash cart
 
- Supplies for induction – See our “Patient Induction Supply Checklist”
 
- Gurney for transporting patient or additional staff
 
Surgery Room
- Clean/disinfect all areas of the room, this includes but is not limited to: overhead lights, surgery tables, anesthesia machines, mayo stand, monitors, etc. Remember when cleaning, start from the overhead lights and work your way down.
 
- Kick bucket or garbage can
 
- Clock with second hand
 
- Anesthesia machine – see our “Basic Anesthesia Machine Set-Up”
 
- Heat source, Baer Hugger, circulating water blanket – See a recent forum discussion
 
- Stethoscope
 
- Pulse Ox and wet gauze pads to help keep the tongue moist
 
- Blood Pressure Monitor
 
- Capnography
 
- Ventilator
 
- Portable crash cart
 
- Laser unit/handle/tips/exhaust PRN
 
- Portable light
 
- Chair
 
- Appropriate surgical supplies for current procedure only
 